Search
English
All Categories
    Menu Close

    banner

    *ราคาที่แสดงเป็นราคาก่อนภาษีมูลค่าเพิ่ม7%นะคะ

    CLEANLINE T-2000 UPS

    Manufacturer: CLEANLINE
    True on-line double conversion design UPS 100% digitized microprocessor controlled Output power factor 0.8 Wide input voltage range 110-300Vac 50/60 Hz frequency converter mode MIMIC LCD for real-time UPS status display Auto self-testing system while turning on UPS ECO mode operation for energy saving Emergency power off (EPO) function Programmable power management outlets Selectable output voltage via LCD panel Cold start function
    SKU: เครื่อง/Set
    banner
    Add friend

    แอดไลน์ พนักงานขาย

    ฿29,900.00
    i h
    Product Files
    SPECIFICATION 
    Input  110-300Vac at 50% load, 220Vac ±25% at 100% load (±27% Option) 50Hz ±10%
    Frequency 50Hz ±10% 
    Output 208/220/230/240Vac 
    AC mode  >87%       
    Tower Model T-2000 
    Power Rating 2kVA/1.6kW        
    Surge protection 220V (IEEEC6100-4-5 level 3)
    Overload protection UPS Automatic bypass if overload between 110% to 130% at 30 seconds and more than 130% at 1.5 seconds
    Short circuit protection UPS Output cut off immediately or input fuse/circuit breaker protection
    Type  Sealed, Maintenance-free lead acid batteries
     Typical recharge time to 90%  4 hours
     Management   Self-test
     Battery protection  Cut off without draining any current when battery is low
     Back up time  15-30 minutes (Depending on computer load)
    Status UPS status, Load level, Battery level, Input/output voltage, Remaining backup time, and Fault conditions
    Tower  421 x 190 x 318
    19” Rack-mount 580 x 438 x 133 (3U)   
    Tower 26 
    19” Rack-mount 29
    0.0 0
    Write your own review Close
    • Only registered users can write reviews
    *
    *
    • Bad
    • Excellent
    *
    *
    *
    SPECIFICATION 
    Input  110-300Vac at 50% load, 220Vac ±25% at 100% load (±27% Option) 50Hz ±10%
    Frequency 50Hz ±10% 
    Output 208/220/230/240Vac 
    AC mode  >87%       
    Tower Model T-2000 
    Power Rating 2kVA/1.6kW        
    Surge protection 220V (IEEEC6100-4-5 level 3)
    Overload protection UPS Automatic bypass if overload between 110% to 130% at 30 seconds and more than 130% at 1.5 seconds
    Short circuit protection UPS Output cut off immediately or input fuse/circuit breaker protection
    Type  Sealed, Maintenance-free lead acid batteries
     Typical recharge time to 90%  4 hours
     Management   Self-test
     Battery protection  Cut off without draining any current when battery is low
     Back up time  15-30 minutes (Depending on computer load)
    Status UPS status, Load level, Battery level, Input/output voltage, Remaining backup time, and Fault conditions
    Tower  421 x 190 x 318
    19” Rack-mount 580 x 438 x 133 (3U)   
    Tower 26 
    19” Rack-mount 29

    *ราคาที่แสดงเป็นราคาที่ไม่รวมค่าติดตั้ง 

    **เครื่องคอมพิวเตอร์ ราคาที่แสดงไม่รวม Microsoft Windows และ POS software เราจำหน่ายแต่โปรแกรมลิขสิทธิ์แท้เท่านั้นนะคะ

    ***ทางบริษัทต้องขอภัยที่จะเรียนให้ทราบว่าเราไม่มีบริการติดตั้งและแก้ไขนอกสถานที่นะคะ

    ****ทางบริษัทขอสงวนสิทธิ์ในการรับคืนสินค้าที่ไม่ได้เกิดจากการบกพร่องของผลิตภัณฑ์ทุกกรณี

    Add friend

    แอดไลน์ พนักงานขาย